www.vikingage.info
  • SM-250SM-250
  • TL-2000TL-2000
  • model-1332Bmodel-1332B
  • model-1422Amodel-1422A
  • model-1022Amodel-1022A
  • model-2502model-2502
  • model-6601model-SPK004A-J
  • model-SPK004A-Jmodel-SPK004A-J
  • CEP-25RRCEP-25RR
  • CEP-2000CEP-2000
  • OTENTO_SUN_VOTENTO_SUN_V
  • OTENTO_SUN_IIIOTENTO_SUN_III
  • BQE-100BQE-100

SHOWA VIBRO-CONVERTER FOR ACCELEROMETER

MODEL-2501

  1. Compact piezoelectoric sensor suitable for measuring application such as high temperature and high vibration level is selectable.
  2. 4 to 20mA output corresponding to vibration values is adjustable within a certain range.
  3. AC output is available for waveform analysis using a FFT analyzer.
  4. This unit is easily connectable to a recorder, indicator or data collector is a remote location.

OPTION

Pick up Model-2300A, 2300A, etc.
Insulated Stud SI-17
Pick up cable LNC-3F-1.5(m), LNC-1A-3(m),etc
Output cable CA4612-**(m)
Digital Monitor Model-2590B

SPECIFICATIONS

Maximum charge input ±1000pC
Maximum input capacity 10000pF
Acceleration measurement(Measured value for detector 5pC/m/s2)
Measuring range Any value is adjustable to maximum output of 20mA within the range of 20m/s2 to 200m/s2
Resolution 0.1m/s2
Frequency range 3Hz-10KHz(-3dB), 5Hz-8KHz(-1dB)
10Hz-5KHz(±0.5dB)
Low-pass filter IN……1KHz cut-off (-3dB), Any frequencyis optionally available(within range of 50Hz to 5KHz). OUT…·10KHz cut-off(-3dB), Fixed
Velocity measurement(Measured value for detector 5pC/m/s2)
Measuring range Any value is adjustable to maximum output of 20mA within the range of 20m/s to 200m/s.
Resolution 0.1mm/s
Frequency range 7Hz-10KHz(-3dB), 10Hz-6KHz(±1dB)
Displacement measurement(Measured value for detector 5pC/m/s2)
Measuring range Any value is adjustable to maximum output of 20mA within the range of 0.2mmp-p to 2mmp-p.
Resolution 0.001mmp-p(1μm)
Frequency range 8Hz-10KHz(-3dB), 10Hz-700KHz(±1dB)
DC output 4-20mA, Load resistance……300Ω
Detection……AVE-PEAK
Control. AC output ±2V full scale (fixed with full scale that is determined according to pick-up sensitivity)
Accuracy 5% or less(80Hz, 10m/s2, sine wave, normal temp)
Linearity 1% or less
Diving power DC11V-26V, 30mA
Temp.&humidity range Operation; 0-50°C, Storage: -20°C-70°C 90% RH or less
Case material Aluminum alloy (Neoprene packing)
Component Device Converter cable: CA4612-3m(3m)

Enquiry | Refer A Friend | More Info

Back to Top

Enquiry Form

Please fill the form below ( * means required fields)

Refer a Friend

Please fill the form below ( all fields are required)

Contact us
* required fields





Captcha image

Can't read the image? Click here to refresh.

Thanks!

Thanks for contacting us. We will get in touch with you soon!

Close this window