Showasaki

Showa Vibro Converter for Accelerometer
Model - 2501

1. Compact piezoelectoric sensor suitable for measuring application such as high temperature and high vibration level is selectable.

2. 4 to 20mA output corresponding to vibration values is adjustable within a certain range.

3. AC output is available for waveform analysis using a FFT analyzer.

4. This unit is easily connectable to a recorder, indicator or data collector is a remote location.

Composition

Pick up Model-2300A, 2300A, etc.
Insulated Stud SI-17
Pick up cable LNC-3F-1.5(m), LNC-1A-3(m),etc
Output cable CA4612-**(m)
Digital Monitor Model-2590B

Specifications

Maximum charge input ±1000pC
Maximum input capacity 10000pF
Acceleration measurement(Measured value for detector 5pC/m/s2)
Measuring range Any value is adjustable to maximum output of 20mA within the range of 20m/s2 to 200m/s2
Resolution 0.1m/s2
Frequency range 3Hz-10KHz(-3dB), 5Hz-8KHz(-1dB)
10Hz-5KHz(±0.5dB)
Low-pass filter IN……1KHz cut-off (-3dB), Any frequencyis optionally
available(within range of 50Hz to 5KHz).
OUT…·10KHz cut-off(-3dB), Fixed
Velocity measurement(Measured value for detector 5pC/m/s2)
Measuring range Any value is adjustable to maximum output of 20mA within the range of 20m/s to 200m/s.
Resolution 0.1mm/s
Frequency range 7Hz-10KHz(-3dB), 10Hz-6KHz(±1dB)
Displacement measurement(Measured value for detector 5pC/m/s2)
Measuring range Any value is adjustable to maximum output of 20mA
within the range of 0.2mmp-p to 2mmp-p.
Resolution 0.001mmp-p(1μm)
Frequency range 8Hz-10KHz(-3dB), 10Hz-700KHz(±1dB)
DC output 4-20mA, Load resistance……300Ω
Detection……AVE-PEAK
Control. AC output ±2V full scale (fixed with full scale that is determined according to pick-up sensitivity)
Accuracy 5% or less(80Hz, 10m/s2, sine wave, normal temp)
Linearity 1% or less
Diving power DC11V-26V, 30mA
Temp. & humidity range Operation; 0-50°C, Storage: -20°C-70°C 90% RH or less
Case material Aluminum alloy (Neoprene packing)
Component Device Converter cable: CA4612-3m(3m)